分光光度法测定铜绿假单胞菌浓度的初步研究
A Tentative Study on the Measuring of the Concentration of Pathogenic Bacteria by Spectrodetection
投稿时间:2009-09-16  修订日期:2009-11-09
DOI:
中文关键词:分光光度法  铜绿假单胞菌  浓度
英文关键词:Spectrodetection  Pseudomonas aeruginosa  concentration
基金项目:
作者单位E-mail
陈寅儿* 宁波大学 chenyiner@nbu.edu.cn 
摘要点击次数: 1860
全文下载次数: 6161
中文摘要:
       采用分光光度法,进行了铜绿假单胞菌(Pseudomonasaeruginosa)培养液浓度测定新方法的研究。结果表明,波长为585nm,以培养基为基准液(空白),铜绿假单胞菌培养液的OD值能较准确地反映其菌量浓度,两者的相关系数在96%以上;铜绿假单胞菌培养液的OD值与菌量的曲线方程为:y=0.0711x+0.5018。
英文摘要:
      With spectrophotometry,a method which was studied to test the concentration of Pseudomonas aeruginosa is described in this paper. The results showed that the Ods of fermentation solution obtained by this method could be fairly corresponding with the concentration of Pseudomonas aeruginosa obtained by traditional method and their co-efficiency is over 0. 96 when the selected wavelengths is 585nm and the culture medium is regarded as curve equation about the Ods of fermentation solution and concentration of bacteria is y=0. 0711x+0.5018.
陈寅儿.2010.分光光度法测定铜绿假单胞菌浓度的初步研究[J].水生态学杂志,31(4):150-152.